Territory Internal - Typical Method for Sealing Vertical Joints 2

 Image of Territory Internal - Typical Method for Sealing Vertical Joints 2

This construction detail documents a typical method for sealing vertical joints in Cemintel Territory internal cladding. It shows panels fixed to double studs with Territory clips and screws, with backing rod and coloured sealant at the joint. An external corner arrangement includes timber battens, spacers, bond breaker tape and a preformed corner. The drawing also includes notes for priming and sealing panel edges.

Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.

Technical information
Junction Type
Sealed vertical panel joint and external corner
Joint Treatment
Backing rod and Territory Coloured Sealant; 5 mm minimum joint
Framing
Double studs at panel joint; stud framing and timber battens at corner
Panel Fixing
Territory panel clips fixed with Territory screws
Corner Components
Preformed external corner, 5 mm spacers and bond breaker tape
Cemintel Logo