Territory Internal - Junction In-line Masonry Wall – Plan View

 Image of Territory Internal - Junction In-line Masonry Wall – Plan View

Plan detail of an in-line junction between Cemintel Territory internal cladding and a masonry wall. Territory panels are shown on battens over stud framing, with a CDS 5 mm spacer and a sealed panel-to-masonry joint incorporating backing rod, primer and Territory coloured sealant. On the opposite face, 10 mm Gyprock plasterboard meets the masonry at a Rondo P35 control joint. The detail is available as an AutoCAD drawing and PDF.

Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.

Technical information
Junction Type
In-line junction between internal cladding and masonry wall
Cladding Assembly
Territory panel on battens with CDS 5 mm spacer
Framing
Stud framing with battens
Panel Junction
Backing rod, primer and Territory coloured sealant
Opposite Wall Face
10 mm Gyprock plasterboard with Rondo P35 control joint
Cemintel Logo

Connect with the Manufacturer

RESEARCH PRODUCT