Territory Horizontal - Typical Parapet-Roof Junction 2

This parapet-to-roof junction detail shows horizontally oriented Cemintel Territory cladding over a masonry wall adjoining a concrete roof. Territory panels are supported on Rondo H515 top hats with panel clips and masonry anchors. At the parapet, an L-form cavity vent runs continuously along the wall, beneath capping supported by exterior-grade timber packing. The drawing also identifies Territory spacers and panel edge fixing positions.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Junction Type
Parapet wall to concrete roof
Substrate
Masonry wall
Cladding Support
Rondo H515 top hats with Territory panel clips and masonry anchors
Parapet Capping
Capping over exterior-grade timber packing with a minimum 5° slope
Cavity Vent
Territory L-form cavity vent, continuous for wall length