Territory Horizontal - Typical Framing Set-Out with 75mm Steel Framing and Territory Pre-formed Corners – Plan View

Plan detail of the typical framing set-out for horizontal Cemintel Territory cladding at a pre-formed corner and vertical panel joint. The drawing shows 75 mm steel stud framing, with double studs at panel joints and a double-flanged Territory joint backing strip. Primer and Territory coloured sealant are specified at vertical panel joints. The detail includes nominal set-out dimensions and maximum stud spacing.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Detail Type
Typical framing set-out, plan view
Framing
75 mm steel studs, with double studs at panel joints
Corner
Territory pre-formed corner
Panel Joint
Double-flanged Territory joint backing strip, primer and Territory coloured sealant
Stud Spacing
600 mm maximum, nominal