Surround External - Eaves-Deflection Head – Sealant filled

Eaves deflection head detail for Cemintel Surround external cladding at a soffit junction. The section shows a sealant-filled deflection gap with bond breaker tape, a J-track or angle at the panel head, and a rivet arrangement allowing for deflection. Surround panels are supported on top hats and horizontal battens over wall wrap and steel stud framing, with plasterboard lining to the interior.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Junction Type
External cladding head at soffit with sealant-filled deflection gap
Deflection Gap
8–20 mm, specified by the project engineer
Head Trim
35 mm J-track or angle, 0.55 BMT, not fixed to top hat
Framing and Support
Steel studs with horizontal battens and top hats
Joint Components
Sealant, bond breaker tape and Surround rivet allowing for deflection