N12-17 - Fielders Neo Roman™ Wall Sheet Joining Detail - Horizontal Fix - Plan View

Plan detail of a horizontal Fielders Neo Roman™ wall sheet junction, showing J and U mould flashings at the sheet join with expansion sealant and sealed blind pop rivets. The cladding is fixed over a permeable membrane and a structural insulated wall frame, with packers on the studs. The drawing forms part of the Neo Roman typical construction details for non-cyclonic conditions.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Junction Type
Horizontal wall sheet join
Flashings
NEO-100 J mould and NEO-104 U mould
Wall Assembly
Structural insulated wall frame with permeable membrane and packers on studs
Joint Components
Expansion sealant and 4.8 mm sealed blind pop rivets fixed to every rib
Drawing Type
Plan view, non-cyclonic construction detail