Base flashing profiles for the Fielders Grandeur® metal sheet cladding system are documented in this non-cyclonic construction detail. Two sections show a standard flashing and an alternative with a squash fold at the exposed edge. Both profiles have a 90-degree lower bend and a minimum 30 mm vertical leg, with other dimensions and angles nominated as required. The detail is available in Revit, AutoCAD and PDF drawing formats.

Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.

Technical information
Flashing Profiles
Standard base flashing and base flashing with squash fold
Profile Geometry
90° lower bend with a minimum 30 mm vertical leg; other dimensions and angles as required
Construction Context
Grandeur® typical construction details, non-cyclonic
Drawing Scale
1:1
Drawing Reference
GRA-203, revision A