C12-11 - Fielders Cadence® Vertical Fix Wall to Fielders Cadence® Roof - Unsupported - Side View

 Image of C12-11 - Fielders Cadence® Vertical Fix Wall to Fielders Cadence® Roof - Unsupported - Side View

This side-view construction detail documents an unsupported junction between vertically fixed Fielders Cadence® wall cladding and a Cadence® roof. The drawing shows the CAD-103 apron flashing notched into the roof profile, a turned-up sheet end and ventilation paths at the junction. It also identifies the wall and roof framing, batten supports, fixing clip and respective membranes. The detail is available in Revit, AutoCAD and PDF drawing formats.

Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.

Technical information
Junction Type
Unsupported vertical wall-to-roof junction
Flashing
CAD-103 apron flashing notched into roof profile
Framing and Supports
Insulated wall frame and roof frame with batten supports
Membranes
Permeable wall membrane and draped impermeable roof membrane
Roof Sheet End
Turned up at wall junction
Fielders Logo

Connect with the Manufacturer