Barestone Surround Timber Battens - External Corner Detail

External corner detail for Cemintel Barestone Surround fibre cement cladding on timber battens. The drawing shows panels meeting at the corner, with battens fixed to the framing over wall wrap or sarking. A vertical gasket band and Cemintel Timber Fix stainless steel screws are identified at the panel-to-batten connection. The detail is available as Revit, AutoCAD and PDF drawing content.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Junction Type
External corner
Cladding System
Barestone Surround fibre cement panels
Support
Timber battens fixed to framing
Wall Membrane
Wall wrap or sarking
Gasket
Vertical gasket band