Barestone External - Base Detail – Drained 2

Drained base detail for Cemintel Barestone External cladding at a concrete footing. The drawing shows the fibre cement panel supported on an Express Wall top hat and horizontal batten fixed to steel stud framing. A flashing sits below the panel, with bond breaker tape and a 5–10 mm gap at the base. Wall wrap is taped to the frame, and plasterboard lining is shown on the interior face.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Junction Type
Drained cladding base at concrete footing
Framing
Steel stud framing with horizontal batten and Express Wall top hat
Base Components
Flashing and bond breaker tape
Base Gap
5–10 mm between panel and flashing
Wall Layers
Wall wrap taped to frame; plasterboard lining