AUS-SURE-036 - BASE DETAIL – DRAINED

Drained base detail for Cemintel Surround fibre cement cladding at a concrete footing. The section shows a Surround panel supported by an Express Wall top hat and horizontal batten fixed to steel stud framing, with wall wrap and internal plasterboard lining. Base flashing extends over the footing, with a 5–10 mm gap below the panel. The detail is available for use in Revit and AutoCAD documentation, with a PDF drawing also included.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Junction Type
Drained cladding base at concrete footing
Cladding System
Cemintel Surround panel with Express Wall top hat
Framing
Steel studs with horizontal batten fixed to frame
Base Flashing
Flashing over footing; 5–10 mm gap below panel
Wall Assembly
Wall wrap and internal plasterboard lining