AUS-SURE-022 - INTER-STOREY JUNCTION WITH FLASHING

 Image of AUS-SURE-022 - INTER-STOREY JUNCTION WITH FLASHING

Inter-storey junction detail for Cemintel Surround cladding, showing flashing at the slab edge between upper and lower panels. The section includes ExpressWall top hats, horizontal battens and air barriers, with provision for slab deflection. An intumescent cavity closer is indicated where required, alongside an optional skirt panel and a window below the junction.

Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.

Technical information
Junction
Inter-storey slab edge with flashing
Cladding system
Cemintel Surround panels
Support components
ExpressWall top hats and horizontal battens
Air barrier
Rigid air barrier with soft air barrier at slab edge
Movement provision
Clearance for slab deflection and a minimum 5 mm gap