AUS-SURE-002 - TYPICAL SURROUND EXTERNAL FIRE RATED INSTALLATION- PRESSURE EQUALIZED VENTILATED CAVITY SYSTEM

A vertical section through a typical Cemintel Surround external fire-rated installation using a pressure-equalised ventilated cavity system. The detail shows Surround panels on top hats and horizontal battens, with support framing, wall wrap and two layers of 16 mm Gyprock Paychek MR plasterboard. The assembly extends from a concrete footing and base flashing to the soffit, with references to separate head and base details.
Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.
Technical information
Detail Type
Vertical section through an external cladding assembly
Cavity System
Pressure-equalised ventilated cavity
Cladding Support
Top hats, horizontal battens and support framing
Wall Lining
Two layers of 16 mm Gyprock Paychek MR plasterboard
Junctions
Soffit above; flashing and concrete footing at base