AUS-BRSE-029 - EAVES-DEFLECTION HEAD – SEALANT FILLED

 Image of AUS-BRSE-029 - EAVES-DEFLECTION HEAD – SEALANT FILLED

Eaves deflection head detail for Cemintel Barestone cladding at a soffit junction. The section shows a sealant-filled deflection gap with bond breaker tape above the panel, and a 35 mm J-track or angle at the panel head. The wall assembly includes top hats, horizontal battens, wall wrap, steel stud framing and plasterboard lining. The soffit incorporates a drip groove.

Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.

Technical information
Junction
Cladding deflection head at soffit
Head treatment
Sealant-filled gap with bond breaker tape
Framing and support
Steel studs, horizontal battens and top hats
Head trim
35 mm J-track or angle, 0.55 BMT, not fixed to top hat
Wall assembly
Barestone panel, wall wrap and plasterboard lining
Cemintel Logo