AUS-BRSE-011 - EAVES-DEFLECTION HEAD – VENTILATED & BASE DETAIL – DRAINED

 Image of AUS-BRSE-011 - EAVES-DEFLECTION HEAD – VENTILATED & BASE DETAIL – DRAINED

Ventilated eaves and deflection head junction with a drained base detail for Cemintel Barestone cladding. The sections show fibre cement panels mounted on top hats and horizontal battens over wall wrap and support framing. At the head, a corrosion-resistant angle connects to the soffit; at the base, flashing and wall wrap terminate above a concrete footing. The drawing identifies the head deflection gap and the clearance at the panel base.

Detail Download. 2D Details / Drafting Views accompany the 3D content and allow for detailed technical construction documentation.

Technical information
Junctions
Ventilated eaves deflection head and drained base
Cladding system
Cemintel Barestone panel on top hats and horizontal battens
Head connection
Corrosion-resistant angle embedded in sealant and fixed to soffit only
Base termination
Flashing over wall wrap at concrete footing; 5–10 mm panel base gap
Wall wrap
Taped to frame or soffit at head and to frame at base
Cemintel Logo

Connect with the Manufacturer

RESEARCH PRODUCT